MOTN-095

MOTN-095: Not Enough Distance for Corner Blending

A warning that the taught positions on the indicated line are too close together for the controller to perform corner blending.

What it means

A warning that the taught positions on the indicated line are too close together for the controller to perform corner blending. The blend can't be completed over such a short distance.

Common causes

Ranked by what technicians most often find, most likely first.

  1. Taught positions on the specified line are spaced too close together to allow a blend.
  2. The programmed corner blend requires more travel distance than the current path provides.

How to fix it

  1. If corner blending is still needed for the line shown, reteach the positions so they are spaced further apart.

Quick facts

Category
Motion
Affected series
R-30iB; R-30iB Mate; R-30iB Plus; R-30iB Mate Plus
Alarm family
MOTN

Verified against FANUC documentation (B-83284EN-1).Last reviewed: 2026-07-12.Editorial process