MOTN-154: PM: I/O data output error
The process monitor function couldn't output its I/O data.
What it means
The process monitor function couldn't output its I/O data. This points to a mismatch between the I/O data defined in ibgn.txt and the data in SENSPS.txt.
Common causes
Ranked by what technicians most often find, most likely first.
- The I/O data in SENSPS.txt doesn't match the I/O data in ibgn.txt.
How to fix it
- Open SENSPS.txt and compare its I/O data against ibgn.txt.
- Correct SENSPS.txt so its I/O data matches ibgn.txt.
Quick facts
- Category
- Motion
- Affected series
- R-30iB; R-30iB Mate; R-30iB Plus; R-30iB Mate Plus
- Alarm family
- MOTN