SRVO-015

SRVO-015: System over heat

The controller cabinet is hotter than its rated limit.

What it means

The controller cabinet is hotter than its rated limit. Same one-minute CPU stop behavior as the fan alarm - the controller protects itself by halting. The question is whether the room is too hot or the cooling has failed.

Common causes

Ranked by what technicians most often find, most likely first.

  1. Ambient temperature above the 45°C controller rating (summer heat, cabinet near an oven or furnace).
  2. Stopped fan or blocked vents.
  3. Faulty thermostat on the main board (rare).

How to fix it

  1. Check ambient temperature at the cabinet; improve ventilation or cool the area if it's genuinely hot.
  2. Verify fans spin and vents/filters aren't clogged - clean or replace.
  3. If it alarms with a cool cabinet and good airflow, the main board thermostat is suspect; image-backup before replacing the board.

Quick facts

Category
Servo
Affected series
R-30iB; R-30iB Mate; R-30iB Plus; R-30iB Mate Plus
Alarm family
SRVO

Related codes

Verified against FANUC documentation (B-83284EN-1).Last reviewed: 2026-07-09.Editorial process