SRVO-131: LVAL / LVAL (PS) alarm (PS control voltage low)

The control supply voltage inside the servo power supply (αiPS) is abnormally low - the power supply's own electronics are underfed.

What it means

The control supply voltage inside the servo power supply (αiPS) is abnormally low - the power supply's own electronics are underfed. Posts per amplifier. Hardware ladder, no configuration fix.

Common causes

Ranked by what technicians most often find, most likely first.

  1. Failed power supply (αiPS).
  2. Failed 6-axis amplifier.
  3. Failed power supply unit.

How to fix it

  1. Replace in FANUC's order: αiPS power supply, then the 6-axis amplifier, then the power supply unit. Power-cycle to clear between attempts.

Quick facts

Category
Servo
Affected series
R-30iB; R-30iB Mate; R-30iB Plus; R-30iB Mate Plus
Alarm family
SRVO

Related codes

Verified against FANUC documentation (B-83284EN-1).Last reviewed: 2026-07-09.Editorial process