SRVO-125: Quick stop speed over
The speed at the moment a quick stop fired (e.g., a high-speed-skip condition being met) was too high for the quick-stop to execute within its limits.
What it means
The speed at the moment a quick stop fired (e.g., a high-speed-skip condition being met) was too high for the quick-stop to execute within its limits.
Common causes
Ranked by what technicians most often find, most likely first.
- Motion speed too high for the quick-stop event in the high-speed skip application.
How to fix it
- Reduce the programmed speed of the motion carrying the quick-stop/skip condition.
Quick facts
- Category
- Warning
- Affected series
- R-30iB; R-30iB Mate; R-30iB Plus; R-30iB Mate Plus
- Alarm family
- SRVO
Related codes
- SRVO-123Fan motor rev slow down
- SRVO-097Pulse not established (track encoder)
- SRVO-096LDAL alarm (track encoder LED broken)
- SRVO-095CMAL alarm (track encoder noise/fault)
- SRVO-094PMAL alarm (track encoder fault)
- SRVO-093SPHAL alarm (track encoder speed excess)
- SRVO-091CRCERR alarm (track encoder data corrupt)
- SRVO-090DTERR alarm (track encoder no response)