SRVO-206

SRVO-206: Deadman switch (SVEMG abnormal)

The deadman was released with the pendant enabled, but the emergency stop line didn't disconnect - the deadman's stop function failed to act.

What it means

The deadman was released with the pendant enabled, but the emergency stop line didn't disconnect - the deadman's stop function failed to act. One configuration exception: robot-isolation setups can trigger this through a settings error.

Common causes

Ranked by what technicians most often find, most likely first.

  1. Fault in the E-stop line related parts.
  2. On controllers fitted with a Robot Isolation hardware switch: incorrect $ROBOT_ISOLC setting.

How to fix it

  1. If the system uses Robot Isolation, verify $ROBOT_ISOLC before condemning hardware.
  2. Otherwise treat as a failed safety function: maintenance-manual diagnosis, qualified personnel, no production until resolved. Power-cycle to clear after repair.

Quick facts

Category
System
Affected series
R-30iB; R-30iB Mate; R-30iB Plus; R-30iB Mate Plus
Alarm family
SRVO

Verified against FANUC documentation (B-83284EN-1).Last reviewed: 2026-07-09.Editorial process