SRVO-227: Amplifier fuse blown (FUSE9)

FUSE9 inside the servo amplifier has blown.

What it means

FUSE9 inside the servo amplifier has blown. FANUC's ladder starts, interestingly, with the fan unit - the usual downstream load on this circuit.

Common causes

Ranked by what technicians most often find, most likely first.

  1. Failed FAN unit loading the fused circuit.
  2. Servo amplifier board fault.
  3. Main board (after image backup).
  4. Side board.

How to fix it

  1. A fuse that blows again has a load behind it. Find the cause rather than feeding it fuses.
  2. With the controller de-energized and locked out, replace the FAN unit first.
  3. With the controller de-energized and locked out, replace the servo amplifier board.
  4. Take an image backup with the controller powered, then de-energize and apply lockout/tagout again before replacing the main board.
  5. With the controller de-energized and locked out, replace the side board last.