SRVO-268: SVOFF1 status abnormal
Chain fault on channel 1 of the SVOFF (servo-off) input - the two redundant SVOFF channels disagree.
What it means
Chain fault on channel 1 of the SVOFF (servo-off) input - the two redundant SVOFF channels disagree.
Common causes
Ranked by what technicians most often find, most likely first.
- Miswiring of the SVOFF signal - typical after integrating external safety devices onto the SVOFF input.
- One-channel contact fault in the connected device.
How to fix it
- With the controller de-energized and locked out, audit the SVOFF wiring on both channels end to end, and repair it per the maintenance manual with the controller still de-energized and locked out.
- After the repair, run the chain release: press and release an E-stop button on the pendant or operator panel, press F4 'RES_1CH' on the Alarm ACTIVE screen [4 Alarm / ACTIVE], then press RESET.